2 x EU-Pal

2500 liters loadvolume

1 x EU/ US-Pal

1500 liters loadvolume

< EU-Pal

770 liters loadvolume

2 x EU-Pal

2500 liters loadvolume

20170331_2500C_transparent_web_k5

SkyCell 2500C
Temperature Range:
+2°C to +8°C

20170331_2500CRT_transparent_Klein_k2

SkyCell 2500CRT
Temperature Range:
+15°C to +25°C

1 x EU/ US-Pal

1500 liters loadvolume

SkyCell1500C__transparent_k3

SkyCell 1500C
Temperature Range:
+2°C to +8°C

20170331_SkyCell1500_CRT_web_k2

SkyCell 1500CRT
Temperature Range:
+15°C to +25°

< EU-Pal

770 liters loadvolume

770C_k1

SkyCell 770C
Temperatur Range:
+2°C to +8°C

770CRT_k1

SkyCell 770CRT
Temperature Range:
+15°C to +25°

SkyCell 2500C +2°C to +8°C

2500C_k1
External Dimensions 1943 x 1522 x 1600 mm
External cube (volume) 4.7 m3
Internal Dimensions 1650 x 1240 x 1220 mm
Door opening 1240 x 1220 mm
Useable volume
2.5 m3
Tara weight ±2%
650 kg
Max gross weight 1850 kg
Volumetric weight 788 kg
Internal temperature range +2° to +8°C
External conditions range –35°C to +65°C
–31°F to +149°F
Storage temperature range –40°C to 70°C
–40°F to +158°F
Download Datasheet SkyCell 2500C Pdf
2500C_k1

SkyCell 2500CRT +15°C to +25°C

2500CRT_k1
External Dimensions 1943 x 1522 x 1600 mm
External cube (volume) 4.7 m3
Internal Dimensions 1650 x 1240 x 1220 mm
Door opening 1240 x 1220 mm
Useable volume
2.5 m3
Tara weight ±2%
650 kg
Max gross weight 1850 kg
Volumetric weight 788 kg
Internal temperature range +15° to +25°C
External conditions range –35°C to +65°C
–31°F to +149°F
Storage temperature range –40°C to 70°C
–40°F to +158°F
Download Datasheet SkyCell 2500CRT Pdf
2500CRT_k1

SkyCell 1500C +2°C to +8°C

1500C_k1
External Dimensions 1530 x 1320 x 1600 mm
External cube (volume) 3.2 m3
Internal Dimensions 1235 x 1040 x 1220 mm
Door opening 1040 x 1220 mm
Useable volume
1.54 m3
Tara weight ±2%
497 kg
Max gross weight 1497 kg
Volumetric weight 539 kg
Internal temperature range +2° to +8°C
External conditions range –35°C to +65°C
–31°F to +149°F
Storage temperature range –40°C to 70°C
–40°F to +158°F
Download Datasheet SkyCell 1500C Pdf
1500C_k1

SkyCell 1500CRT +15°C to +25°C

1500CRT_k1
External Dimensions 1530 x 1320 x 1600 mm
External cube (volume) 3.2 m3
Internal Dimensions 1235 x 1040 x 1220 mm
Door opening 1040 x 1220 mm
Useable volume
1.54 m3
Tara weight ±2%
497 kg
Max gross weight 1497 kg
Volumetric weight 539 kg
Internal temperature range +15° to +25°C
External conditions range –35°C to +65°C
–31°F to +149°F
Storage temperature range –40°C to 70°C
–40°F to +158°F
Download Datasheet SkyCell 1500CRT Pdf
1500CRT_k1

SkyCell 770C +2°C to +8°C

770C_k1
External Dimensions 1200 x 1000 x 1600 mm
External cube (volume) 1.92 m3
Internal Dimensions 915 x 690 x 1200 mm
Door opening 690 x 1220 mm
Useable volume
0.75 m3
Tara weight ±2%
315 kg
Max gross weight 685 kg
Volumetric weight 320 kg
Internal temperature range +2° to +8°C
External conditions range –35°C to +65°C
–31°F to +149°F
Storage temperature range –40°C to 70°C
–40°F to +158°F
Download Datasheet SkyCell 770C Pdf
770C_k1

SkyCell 770CRT +15°C to +25°C

770CRT_k1
External Dimensions 1200 x 1000 x 1600 mm
External cube (volume) 1.92 m3
Internal Dimensions 915 x 690 x 1200 mm
Door opening 690 x 1220 mm
Useable volume
0.75 m3
Tara weight ±2%
315 kg
Max gross weight 685 kg
Volumetric weight 320 kg
Internal temperature range +15° to +25°C
External conditions range –35°C to +65°C
–31°F to +149°F
Storage temperature range –40°C to 70°C
–40°F to +158°F
Download Datasheet SkyCell 770CRT Pdf
770CRT_k1

New Insulation ISOPET©

Best-in-Class cooling

Technology

SkyCell’s performance to maintain +2 to +8°C at extreme temperatures
such as +68°C or –35°C are possible due to the combination of
the proprietary technologies ISOPET © and a failsafe high
performance phase change material.

07-Monitoring_k1

Cloud Monitoring

Near real–time monitoring
SkyCell containers permanently monitor the inside and outside temperature.

Today‘s monitoring applications include:
• Internal quality processes
• Consignment stock
• Delayed shipments (shipments that do not leave the factory/warehouse)
• Backup to Pharma companies own usb temperature monitoring devices.

08-Recharging_k1

Recharging

Cold-energy battery
The SkyCell 770C and 1500C “cold-energy battery” operates only on temperature differences – so energy and runtime are only reduced when the temperature is greater than +5°C and lower than +2°C. If at some point during its journey the SkyCell unit is placed back into a refrigerated area, such as a warehouse or chilled truck at +5°C, the unit starts to recharge again. Also, if the temperature is consistently between +2°C and +5°C, no energy is consumed and there is no reduction in the container’s runtime.

See the recharging-effect on your supply chain consult the SkyCell Transport Planner

09-Sustainability_k1

Sustainability

Up to 50% CO2 savings
The lower weight and higher net volume efficiency of SkyCell containers ensure that CO2 emissions are 20% to 50% lower compared to active RKNs.

Recycling
All SkyCell containers are Swiss Made and made from 100% recyclable materials. At the end of their life cycles, the container materials are separated and recycled in a home for handicapped people.

Lightweight and recyclable – SkyCell’s contribution to sustainability

20150528_R&D_Roadmap_gross_k5